Technology & Verification

The Right Tools. Proven Results.

Advanced application technology, chemistry tailored to each environment, environmental monitoring and measurable verification. We don't just clean and disinfect; we prove it worked.

Fogging in Action

Whole-Space Disinfection, Fast

Fogging disperses an ultra-fine mist that reaches large open areas, overheads and hard-to-reach spaces, treating an entire warehouse, gym or arena in a fraction of the time manual application takes. For disinfection we use ULV systems with products whose EPA label allows fogging; thermal fogging is reserved for odor and flying-insect control where labels allow.

  • Large open spaces
  • Outbreak response
  • Label-approved products only
  • Label re-entry times observed
Compare Fogging Technologies
Electrostatic vs. ULV vs. Thermal

Three Technologies, Three Different Jobs

These three technologies are often grouped together, but they work very differently. Choosing the right one depends on the space, the surfaces, the product label and whether the area is occupied.

Electrostatic Spraying

Charged-droplet surface coverage

Electrostatic sprayers pass the solution over an electrode that gives each droplet a positive charge. Charged droplets repel each other, so they spread evenly, and are attracted to surfaces, wrapping around objects to coat sides, undersides and edges that conventional spraying misses.

How It Works

  • An electrode at the nozzle charges each droplet as it is sprayed
  • Droplets repel each other and spread evenly instead of pooling
  • Attraction to surfaces wraps coverage around desks, rails, chairs and equipment
  • Larger droplets are designed to land on surfaces, not hang in the air

Best For

  • Classrooms, daycare rooms, offices and break rooms
  • Clinics, patient rooms and waiting areas
  • Locker rooms, weight rooms and gym equipment
  • Restrooms, buses and other high-touch spaces

Our Protocol

  • Only products whose label allows electrostatic application
  • Surfaces cleaned first where soil is present
  • Surfaces left wet for the full label contact time
  • PPE per label; results verified with ATP on representative touch points

ULV Fogging

Ultra Low Volume cold fogging

ULV cold foggers use a high-velocity air stream, with no heat, to shear water-based disinfectant into fine droplets, commonly about 5–50 microns. The droplets stay suspended and drift through the space, reaching large air volumes, overheads and hard-to-reach surfaces.

How It Works

  • A motor-driven blower creates a high-velocity, low-pressure air stream
  • The air shears the solution into fine, adjustable droplets
  • Very little liquid is used per square foot, so surfaces wet evenly without pooling
  • No heat means water-based products and low fire risk

Best For

  • Warehouses and distribution centers
  • Gyms, arenas and field houses
  • Outbreak response and whole-room treatment
  • Spaces with complex structures or high overheads

Our Protocol

  • Only products whose label allows fogging application
  • Area vacated; doors closed, signs posted, HVAC and smoke detectors managed as required
  • Exposed food, packaging and sensitive equipment covered or removed
  • Label contact time and re-entry interval observed before re-occupancy

Thermal Fogging

Heat-generated dense fog

Thermal foggers use heat to vaporize a fogging solution. When the vapor meets cooler air it condenses into a dense, visible fog of very fine droplets, commonly cited at about 8–20 microns, that penetrates deep into large volumes and dense spaces.

How It Works

  • A heated chamber vaporizes the solution, which condenses into a thick, visible fog
  • The visible cloud lets operators see exactly where coverage reaches
  • Very fine droplets penetrate voids, overheads, drains and dense areas

Best For

  • Odor control: smoke, fire-restoration and musty odors with labeled deodorizers
  • Flying-insect and vector control with labeled insecticides (licensed applicators)
  • Disinfection only where a product label allows thermal fogging, which in the U.S. is mostly limited to agricultural and animal premises

Our Protocol

  • Only products whose label allows thermal fogging; heat can break down many disinfectants, such as hydrogen peroxide and hypochlorous acid
  • Never in occupied spaces or near exposed food or packaging
  • Fire safety: ignition sources controlled, smoke detection managed, trained operators
  • Insecticide applications performed by licensed applicators; label re-entry times observed
FeatureElectrostatic SprayingULV (Cold) FoggingThermal Fogging
How it worksElectrically charges droplets so they're attracted to surfacesHigh-velocity air shears liquid into fine droplets, no heatHeat vaporizes the solution, which condenses into dense fog
Droplet sizeLarger droplets designed to land and wrap on surfacesFine, commonly about 5–50 micronsVery fine, commonly about 8–20 microns
VisibilityLight mistLight, hard-to-see mistThick, highly visible fog
Typical carrierWater-based disinfectantsWater-based disinfectantsFogging solutions, often oil-based for insecticides
Primary targetHigh-touch surfacesIndoor air volume and hard-to-reach surfacesOdors, flying insects, voids and large unoccupied volumes
Best environmentsClassrooms, offices, clinics, locker rooms, gymsWarehouses, gyms, arenas, outbreak responsePerimeters, drains, cold storage, vector control
Typical chemistriesQuats, accelerated hydrogen peroxide, silver dihydrogen citrate, hypochlorous acidHydrogen peroxide (often with silver), hydrogen peroxide/peracetic acid, hypochlorous acidQuats (some with glutaraldehyde), deodorizers, labeled insecticides
Label availability (U.S.)Wide: EPA created an expedited process to add electrostatic directions, and many disinfectants carry themModerate: often registered as a system (specific product + specific fogger)Limited: few disinfectant labels allow it, mostly for animal premises
Key benefitsEven coverage, less waste, fast turnoverNo heat, large indoor coverage, low residueDeepest penetration, visible coverage, fast large-area treatment
Key considerationsProduct must be labeled for electrostatic use; full contact timeArea vacated; product labeled for fogging; coverage hard to seeHeat and fire risk; possible residue; never occupied or food-exposed areas

Our rule: fogging and spraying supplement cleaning; they never replace it. We clean first, choose the technology that fits the space, use only products whose label allows that application method, and observe every contact time and re-entry interval. Learn more in our guides: Disinfectants by Application Method and Fogging and COVID-19: What the Evidence Says.

Droplet sizes are typical ranges reported in equipment literature and vary by machine, nozzle and settings.

Equipment & Deep-Cleaning Technologies

Inside Tanks, Lines and Equipment

For process equipment, we use automated Clean-in-Place systems and waterless dry ice blasting to clean thoroughly with the least downtime. The table below summarizes when to use each of our application methods.

360° CIP Spray Systems

Automated Clean-in-Place for tanks and vessels

Clean-in-Place systems clean tanks, piping and process lines without disassembly. Inside vessels, 360° spray devices make sure every interior surface is reached on every cycle.

How It Works

  • Static spray balls flood the vessel surface with a steady sheet of cleaning solution
  • Rotary spray heads and rotating jet heads sweep high-impact streams across the full 360° interior, adding mechanical cleaning power
  • Programmed cycles control time, temperature, chemical concentration and flow

Best For

  • Mixing and storage tanks, kettles and silos
  • Product piping, heat exchangers and fluid systems
  • Plants that need repeatable, documented cleaning with minimal downtime

Our Protocol

  • Spray coverage confirmed (for example, with riboflavin coverage tests) when devices are installed or changed
  • Cycle parameters recorded for every run: time, temperature, concentration and flow
  • Rinse water and surfaces verified with ATP and, where required, microbial testing
  • Deviations investigated and corrected before the line is released

Dry Ice Blasting

Waterless, non-abrasive decontamination

Dry ice blasting propels solid CO2 pellets at about −109 °F (−78.5 °C) against a surface. The impact and thermal shock loosen residue, and the pellets turn directly into gas, leaving no water and no blasting media behind.

How It Works

  • Removes baked-on residue, carbon, grease, dust and build-up without abrasion
  • No water, so it can be used where moisture would create microbial risk or damage equipment
  • Equipment can often be cleaned in place with minimal disassembly, cutting downtime

Best For

  • Ovens, conveyors, molds, mixers and dry-processing lines
  • Electrical cabinets, motors and controls (de-energized)
  • Bakery, snack, milling and other low-moisture environments

Our Protocol

  • Area ventilation and CO2 monitoring in enclosed spaces
  • Hearing, eye and cold protection for operators
  • Loosened debris collected and removed
  • Followed by sanitizing as defined in the validated SSOP, then verified
At a Glance

Which Method When

MethodWhat It Does BestOccupancyKey Requirement
ULV FoggingTreats large air volumes and hard-to-reach areasArea vacated during treatmentProduct labeled for fogging; re-entry interval observed
Thermal FoggingOdor and flying-insect control in voids and large unoccupied volumesArea vacated; never occupied or food-exposed areasProduct labeled for thermal fogging; fire safety controls
ElectrostaticFast, even coverage of many surfaces and touch pointsPer product labelProduct labeled for electrostatic use; full contact time
360° CIPRepeatable cleaning of tanks, lines and closed systemsEquipment offlineValidated cycle with recorded parameters
Dry Ice BlastingWaterless removal of hard residue on equipmentEquipment offline; ventilated areaCO2 monitoring and PPE; followed by sanitizing
360° Clean-in-Place

Repeatable, Documented Cleaning Inside Every Tank

Rotary and static spray devices reach the full interior of tanks and vessels, with validated cycles that record time, temperature, concentration and flow every run.

  • Tanks & vessels
  • Validated cycles
  • Recorded parameters
Clean-in-Place

A Validated CIP Cycle

A typical CIP sequence, adjusted to your product, soils and equipment. Every cycle is built on the four factors that control cleaning results.

Step 1

Pre-Rinse

Removes loose soil and product residue.

Step 2

Alkaline Wash

Caustic solution breaks down fats and proteins.

Step 3

Intermediate Rinse

Flushes out loosened soil and detergent.

Step 4

Acid Wash

Removes mineral scale and milkstone, as needed.

Step 5

Sanitize

Approved sanitizer, then final rinse if the label requires it.

T

Time

Each step runs long enough to do its job.

A

Action

Flow, pressure and spray impact provide the mechanical force.

C

Concentration

Chemistry at the right strength, verified by titration.

T

Temperature

Solutions held at the temperature the cycle was validated at.

Dry Ice Blasting

Waterless Cleaning for Sensitive Equipment

Solid CO2 pellets lift baked-on residue and build-up without water, abrasion or secondary waste, often cleaning ovens, conveyors and electrical components in place.

  • No water
  • Non-abrasive
  • Less disassembly
Tailored Chemistry

The Right Chemistry for Each Environment

A daycare, a hospital and a food plant need very different products. We match chemistry to the surfaces, soils, pathogens and regulations of each site, and every product is used according to its label.

Daycare & Education

Safe for Children's Spaces

  • Lower-toxicity, low-odor products for occupied rooms
  • Food-contact sanitizers for tables, high chairs and mouthed toys, per label
  • Disinfectants for diapering areas, restrooms and high-touch points
  • Products listed under EPA's Design for the Environment program where available
Healthcare

Hospital-Grade Disinfection

  • EPA-registered hospital disinfectants with claims for the pathogens of concern
  • Sporicidal products from EPA's List K where C. difficile is a concern
  • Contact times that fit real workflows in patient and exam rooms
  • Compatibility with surfaces and medical equipment per manufacturer guidance
Food Processing

Chemistry Matched to the Soil

  • Alkaline and chlorinated alkaline cleaners for fats and proteins
  • Acid cleaners for mineral scale and hard-water deposits
  • Food-contact sanitizers such as peracetic acid (PAA), quaternary ammonium and chlorine, used per label
  • Concentrations verified by titration and documented

We select products from established manufacturers trusted in schools, daycares, hospitals and food plants, including:

Brand names are trademarks of their respective owners. Brochures and technical literature are in our product literature library. Products are selected for each site based on surfaces, soils, label claims and regulations.

Verified With ATP

Proof in Seconds

A swab and a handheld luminometer show how much organic residue is left on a surface. Every test point is logged, so you get proof that cleaning worked, not just a checklist.

  • Pass / caution / fail
  • Logged by location
  • Trended over time
Validation & Verification

Measured, Not Assumed

Clean has to be proven. Our programs separate three things that are often confused, and document each one.

Validation

Prove the Protocol Works

Before a protocol goes into routine use, we show it achieves the intended result under real, worst-case conditions, using ATP and, where required, microbial and allergen testing before and after cleaning. Validation is repeated when products, equipment or processes change.

Verification

Confirm It Was Done Right

Ongoing checks that each cleaning followed the validated protocol: ATP swabs at defined points, visual pre-operational inspections, chemical titrations and CIP cycle records.

Monitoring

Track It Over Time

Results are logged and trended so drift is caught early. Repeat failures trigger a root-cause review and a protocol adjustment.

ATP Testing

Results in Seconds, Not Days

ATP (adenosine triphosphate) is found in all living cells and in most food residue. An ATP swab collects it from a surface; a handheld luminometer uses an enzyme reaction to produce light and reports the result in Relative Light Units (RLU).

Higher readings mean more organic residue left behind. Because results come back in seconds, a surface that fails can be re-cleaned and re-tested before production starts.

ATP measures overall cleanliness. It does not identify specific organisms, so we pair it with microbial swabs, allergen tests and environmental monitoring where your food safety plan calls for them. We work with industry-standard ATP systems from manufacturers such as Hygiena and Neogen.

How an ATP Check Works

PASSCAUTIONFAIL
1

Test points and pass, caution and fail limits are set for each surface type during validation.

2

After cleaning, the surface is swabbed and read in the luminometer.

3

Pass: released. Caution: re-clean recommended. Fail: re-clean and re-test before use.

4

Every result is logged by location and date for trending and audit records.

Microbial Swabs

Indicator organisms and environmental monitoring, sent to an accredited lab where required.

Allergen Tests

Rapid protein or allergen-specific tests to verify changeover cleaning.

Chemical Titration

Test kits and strips confirm cleaner and sanitizer concentrations.

CIP Data Records

Time, temperature, concentration and flow captured for every cycle.

Environmental Monitoring

Testing the Environment, Not Just the Surface

An Environmental Monitoring Program (EMP) samples surfaces, air and water throughout your facility to confirm that sanitation is controlling microorganisms and allergens, and to find problem areas before they reach product. Sampling sites are organized by hygienic zone, based on how close each area is to product.

Zone 1

Food-Contact Surfaces

Surfaces that touch product: slicers, conveyors, fillers, utensils, tables.

  • ATP and indicator organisms after sanitation
  • Pathogen testing per your risk assessment and food safety plan
Zone 2

Adjacent Non-Contact

Surfaces close to product: equipment frames, guards, control panels, drip shields.

  • Indicator organisms
  • Pathogens such as Listeria spp. where relevant
Zone 3

Processing Area

Non-contact surfaces in the room: floors, drains, walls, carts, forklifts.

  • Pathogen and indicator sampling
  • Drains as early-warning sites
Zone 4

Outside Processing

Areas outside the room: locker rooms, warehouses, hallways, maintenance.

  • Periodic sampling to find sources that could be carried in

Hygienic zones for environmental monitoring are separate from the buffer zones used in our pest management program.

What We Can Test

Environmental Analyses

AnalysisWhat It Tells YouMethodTypical Use
ATPOverall organic residue left after cleaningSwab and handheld luminometer, results in secondsPre-operational verification of sanitation
Indicator OrganismsGeneral hygiene level: aerobic plate count, Enterobacteriaceae, coliforms, yeast and moldSponge or swab samples, accredited labTrending sanitation effectiveness over time
PathogensPresence of Listeria spp. / L. monocytogenes, Salmonella and others relevant to your productsEnvironmental sponges, accredited labVerifying control in Zones 2–4, and Zone 1 per your food safety plan
AllergensAllergen residue after changeoversRapid protein or allergen-specific swabs, lab confirmationValidating and verifying allergen cleaning
Air QualityAirborne bacteria, yeast and moldSettle plates or active air samplersPackaging rooms, ready-to-eat areas, cleanrooms, clinics
WaterMicrobial quality of water and ice used in the processWater samples, accredited labPotable water, ice and process water verification

A Written Sampling Plan

Sites, zones, test types and frequencies defined in writing, with sites rotated so the whole facility is covered over time. Samples are taken during production and after sanitation to see the full picture.

Response to Positives

Each positive triggers a defined response: intensified cleaning, re-sampling, and vector swabbing around the site to trace the source. Findings close to product are escalated to your QA team immediately.

Trending & Root Cause

Results are mapped and trended by site and zone. Repeat positives point to harborage sites, equipment design issues or gaps in sanitation that we fix at the root.

Microbiological and pathogen analyses are performed by accredited third-party laboratories. Sampling plans are built around your food safety plan, customer requirements and applicable regulations.

See all environmental services, including indoor air quality and odor control →

KPIs & Reporting

Effectiveness You Can See

We track the indicators that show whether protocols are working, and share them with you in regular reports.

Verification

ATP First-Pass Rate

Share of test points passing on the first swab.

Verification

Re-Clean Rate

How often surfaces need re-cleaning before release.

Inspection

Pre-Op Pass Rate

Pre-operational inspections passed before start-up.

Chemistry

Concentration Compliance

Titrations within the specified range.

Execution

Schedule Completion

Master sanitation tasks completed on time.

CIP

Cycle Compliance

CIP runs meeting all validated parameters.

Response

Corrective Actions Closed

Findings closed on time with verification.

Pest Control

Activity by Zone

Pest activity trended by zone and device.

KPIs and targets are agreed with your team at the start of the program and reviewed in regular reports, so you always know how well your protocols are performing.

See What Verified Clean Looks Like

We'll assess your facility, recommend the right technologies and chemistry, and show you how results will be measured.